Call an engineer · (216) 921-2240
  1. Home
  2. Applications
Ultrasonic Processing Applications

Applications for Ultrasonic Liquid Processing

Ultrasonic cavitation can be applied to emulsification, dispersion, extraction and other liquid-processing operations. The result depends on the material, formulation and processing conditions.

Two ultrasonic converter and horn stacks mounted on a single stainless steel flow cell, with tri-clamp connections at each end
5–40 L/hrAcross three configuration tiers
20–30 nmDroplet size, volume-weighted by DLS
2.0–8.0 kWStandard and custom configurations
316L stainlessWetted parts, no welds, electropolished

What does ultrasonic processing do to a liquid?

A titanium horn vibrates at 20 kHz. The liquid cannot follow it, so it tears, forming vapor cavities that collapse microseconds later.

Cavitation creates intense localized shear that can break droplets apart, rupture cell walls, disperse agglomerates and remove dissolved gas. The result depends on the material and process conditions.

Amplitude is what makes it work. Our systems reach 100 micron amplitude with the 2:1 half-wave Grade 5 titanium booster fitted. Delivered power at the horn is 1.2 to 1.6 kW on a 2,000 W generator. That is a measured figure, not a nameplate one, and it moves with viscosity.

One mechanism, four outcomes A 20 kHz horn drives cavitation. Depending on the material, the same collapsing bubbles emulsify oil into droplets, rupture cell walls to release contents, drive dissolved gas out of a liquid, or separate agglomerated particles without making them smaller. 20 kHz · 100 micron amplitude · 1.2–1.6 kW delivered · cavitation Emulsify One phase becomes 20–30 nm droplets Extract The cell wall ruptures, contents release Degas Dissolved gas nucleates and leaves Disperse Clumps break, particles unchanged
Ultrasonic cavitation can be used for emulsification, extraction, degassing and dispersion.

Why Nanoemulsify?

Nanoemulsification is commonly used to improve water compatibility, control particle size and improve clarity.

Compatibility

Helps oil-based actives disperse evenly in water-based formulations.

Bioavailability

Cannasol measures droplet size, distribution and stability.

Appearance

Small droplet sizes can improve clarity in finished formulations.

The Applications in Detail

The cavitation mechanism is the same, but equipment, wetted materials and process requirements vary by application.

Below are the applications we are asked about most often. Contact us if your process is not listed.

1

Food and Beverage Emulsion

Oil-in-water nanoemulsions for products a person drinks or eats. Reducing the oil phase to a few tens of nanometers gives a concentrate that disperses completely and stays dispersed.

Two specifications matter. Kinetic stability needs droplets at 200 nm or below. Translucency needs essentially nothing above 100 nm. Everything wetted is 316L stainless, machined from solid, no welds, electropolished.

  • Functional Beverages
  • Concentrates and Shots
  • Gummies and Chewables
  • Tinctures and Sprays
  • Sauces and Dressings
  • Flavor and Fragrance
Jacketed mixing tank on load cells beside an enclosed ultrasonic flow cell and pump cart in the Cannasol cleanroom
Emulsion production in our own cleanroom. Jacketed tank on load cells, feeding the ultrasonic stage.
2

Nutraceutical and Botanical Formulation

The same process applied to oil-soluble compounds a formulator needs in a water-based product. Classes we see regularly: oil-soluble vitamins, alkaloids, terpenes, curcuminoids, carotenoids, phytosterols, polyphenols and coenzymes.

Powder is a real output format. Where the finished product is a dry sachet, an instant mix or a tablet, the emulsion has to survive drying, and that is decided before the first batch.

  • Oil-Soluble Vitamins
  • Alkaloids
  • Terpenes
  • Curcuminoids
  • Carotenoids
  • Isolates and Distillates
Warehouse shelf of labeled Cannasol containers: High-Loader Part B in white tubs with red lids, High-Loader Part A in bottles, and a tray of filled bottles
High-Loader Part A and Part B on the shelf, lot-numbered.
3

Extraction and Cell Lysis

Cavitation ruptures cell walls. Once the wall is broken, the solvent reaches the contents directly instead of waiting on diffusion, so the same extraction finishes in less time and often cooler.

The UXS-2000 is built for this. A 100 L jacketed 316 stainless tank rated to 100 psi, a 2,000 W processor in the lid, a 40 mm titanium horn, a VFD mixer and a 3,000 W chiller. Made to order. Smaller work runs in a reactor chamber on a CT-2000, 5 to 50 L, minimum 1.8 kW.

  • Botanical Extraction
  • Mushroom and Fungal
  • Cell Lysis
  • Ethanol and Water as Solvents
Two CT-2000 generators, an enclosed flow cell, pump and jacketed tank in the Cannasol lab
Sonication in our lab. Two generators, an enclosed flow cell, pump and jacketed tank.
4

Degassing and Deaeration

Cavitation gives dissolved gas somewhere to go. Bubbles nucleate, merge and rise, taking entrained air with them. No vacuum chamber and no heating step, which suits heat-sensitive material and in-line running.

Batch work runs in the reactor chamber, 5 to 50 L, minimum 1.8 kW. Continuous work runs through the flow cell. We publish no removal percentage: it depends on your liquid, your starting gas load and your residence time.

  • Bottling Lines That Foam
  • Surface Finish on Coatings
  • Bubble-Free Set in Epoxies
  • Even Burn in Poured Wax
  • Rancidity in Fats and Oils
  • Consistency in Creams
Ultrasonic reactor chamber flow cell CNC machined from 316L stainless steel
The reactor chamber. Milled from one block of 316L, no welds, electropolished.
5

Dispersion and De-Agglomeration

Dry powders arrive clumped. The clumps are held together weakly. Cavitation breaks them apart and wets each particle, which separates the particles rather than making them smaller.

Separating them raises exposed surface area, and surface area is what most powder properties depend on. In a pigment that reads as color strength and opacity; in a functional powder, as a suspension that has not settled out on arrival.

  • Pigment Dispersion
  • Metal Oxide Suspensions
  • Carbon Black
  • Mineral Fillers
  • Wet Milling
Gloved hand adding powder to a beaker of liquid on a laboratory balance
A powder wetting out into liquid, weighed to 0.1 g before it goes in.
6

High-Temperature and Exotic Materials

We build ultrasonic systems for molten metal treatment and polymer processing. These use different wetted materials, horn geometry and thermal design from the sanitary equipment.

There is no configurator and no published price. Call with the material, the process temperature and the volume.

  • Molten Metal Treatment
  • Polymer Processing
  • Custom High-Temperature Builds
CNC turning a titanium component in the Cannasol machine shop
We cut every horn and booster we sell, in our own shop.
Material Requirements

Free-flowing liquids are generally suitable for ultrasonic processing. Higher-viscosity materials may require application-specific testing.

How do you scale from bench to production?

By adding stages, not by making one stage bigger. A single CT-2000 runs 5 to 10 L/hr. A second processor in series takes system power from 2.0 to 4.0 kW and throughput to the 10 to 20 L/hr tier. Custom configurations run to 8.0 kW.

Amplitude stays constant. Each stage does the same thing to the liquid as the one before it, so bench parameters are production parameters.

A 10 L batch runs about 1 hour 40 minutes of emulsification and about 25 minutes of post-emulsification mixing, at 55 to 60 °C. Both stages are required. Cycle time scales with volume, not concentration.

Ultrasonic converter and horn on a laboratory stand with the horn tip immersed in a beaker of liquid Ultrasonic converter and horn mounted in a stainless reactor chamber with tri-clamp fittings and hose barb connections, configured for continuous flow

The same 20 kHz stage, run batch in a beaker or inline in a reactor chamber.

Describe Your Process

The active, the finished product, your target throughput. We will tell you which tier fits and what it will not do.

Cannasol Technologies LLC8101 Uzita Drive
Sarasota, Florida 34240, United States

(216) 921-2240

josh.detzel@cannasolusa.com

Monday–Friday, 9:30 AM–5:30 PM Eastern

Contact Us

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
© Copyright 2026 Cannasol Technologies LLC Privacy policy · (216) 921-2240