Call an engineer · (216) 921-2240
  1. Home
  2. FAQ
Questions buyers actually ask

Ultrasonic Processing FAQ

Grouped by process rather than by product, because that is how the questions arrive.

Sizing a System

1. I need about 15 liters an hour. Which system do I need?

The turnkey package. The CT-2000 base package runs 5–10 L/hr in continuous flow. The turnkey package, which adds a second processor and automation, runs 10–20 L/hr. Above that, a custom 8.0 kW system reaches 20–40 L/hr and is quoted per application.

Actual throughput varies with the material and target droplet size. The lower end of each is a difficult-to-emulsify active at a demanding target droplet size. If 15 L/hr is a hard requirement rather than a target, tell us the active and we will say which end of the range you are likely to land on.

2. Can I start small and scale up later, or will I have to replace everything?

You can scale without replacing. A second CT-2000 processor is $18,995 and adds a stage to a system already installed. The IAS-2100 automation controller retrofits at $10,995. Tanks, chillers and heat exchangers are all separate line items you can add later.

What does not scale is jumping to the 20–40 L/hr tier. That is a custom 8.0 kW build rather than more CT-2000s bolted together, because cooling and automation have to be sized to the delivered power as one system.

3. I already have a 20 kHz sonicator. Can I just buy the flow cell?

Often, yes. Check delivered power first. Our reactor chambers and horns are compatible with an array of 20 kHz ultrasonic systems (Branson, QSonica, Sonics and Materials, etc.). The reactor chamber requires a minimum 1.8 kW system; the 40 mm flowcell horn requires a minimum 2.0 kW.

Below those power thresholds, adding a chamber will not correct the underlying limitation. Call with the model number and we will look it up.

4. What is the smallest thing you sell that actually works?

The CT-2000 base package at $20,995. That is a complete continuous-flow chain minus cooling. There is no cheaper complete system, and we do not sell a hobbyist tier.

Budget for cooling on top. A 1600W chiller is $1,895 and an 18″ sanitary heat exchanger is $1,095. Adding both to the base package totals $23,985. A sound enclosure at $2,195 takes it to $26,180.

Process and Results

5. What droplet size can I actually expect?

As small as 20–30 nm, volume-weighted average by DLS. NanoOptimizer™ yields 20–100 nm depending on usage conditions. Where you land depends on the active, the carrier oil, the surfactant ratio and residence time.

Ask any supplier which average they are quoting. A number-weighted average reads smaller than a volume-weighted average on the identical sample, and comparing one against the other compares nothing. Ask for the polydispersity index alongside it, and whether the sample was diluted before measurement.

6. Why is my emulsion cloudy when it is supposed to be clear?

Your droplets are still too large. Excellent clarity requires essentially zero particles above 100 nm. The tail of the distribution makes a batch cloudy, not the average.

Three usual causes. Insufficient amplitude, which no amount of extra generator wattage fixes. Too little residence time, so run more passes and measure between them. Or a surfactant ratio that is wrong for the oil, which is a formulation problem rather than an equipment problem.

7. How many passes through the flow cell do I need?

Pass count is material-specific and should be determined by measurement. Droplet size falls quickly on the first passes and then plateaus. The plateau is where you stop. Further passes add heat and cost without reducing size.

For reference, a 10L batch containing 1 kg of distillate made with High-Loader™ takes about 1 hour 40 minutes to emulsify, plus about 25 minutes of post-emulsification mixing. Run temperature is 55–60 °C.

8. Is the process repeatable, or does it depend on the operator?

Manually, it depends on the operator. With the IAS-2100, it does not. The controller holds pressure, flow and temperature setpoints through sanitary sensors, logs the run, and carries intelligent alarms with a failsafe. It has an overnight mode.

At $10,995 it suits production to a specification a customer will test against, rather than a single R&D bench.

9. What yield improvement will I see?

We do not publish a yield figure. Yield depends on your biomass or active, your solvent, your cycle and your downstream steps. A number measured on our material would not predict yours, and quoting one would be a claim we could not substantiate for your process.

Ask any supplier for the material, the configuration and the measurement method behind a yield figure.

Cooling, Noise and Safety

10. Do I really need a chiller, or can I run without one?

You need cooling. Essentially all the acoustic energy delivered into the liquid becomes heat. A 1.6 kW process is also a 1.6 kW heater. Our flow cell is non-jacketed by design, so cooling happens outside the cavitation zone.

A short bench batch runs without one. Sustained running without cooling will cook a heat-sensitive active and will not hold a droplet size target. Size the chiller above delivered power, not equal to it. A 1.64 kW chiller has no margin on a 1.6 kW process.

11. How loud is it, and do I need an enclosure?

Source level is in excess of 105 dBA at 24 in. from the flow cell, measured by us. Noise reducing earmuffs or a sound enclosure are required.

The sound enclosure is QSonica part 4475, which we resell at $2,195. QSonica publishes an average 30 dBA reduction for it. We do not publish an enclosed dBA figure. An average reduction across the spectrum is not attenuation at the dominant frequency, and “in excess of 105” is a floor rather than a level.

Check the interior dimension against your flow cell and stand before ordering: interior is 12 × 14 × 28.5 in. and the stand is not included.

12. What are the wetted materials, and is this food safe?

Wetted parts are 316 and 316L stainless steel, Grade 5 titanium, and platinum-cured medical-grade silicone tubing. The reactor chamber is CNC-milled from one block of 316L, with no welds, and electropolished. The magnetic-drive pump has stainless wetted surfaces.

Sonication introduces a small amount of titanium from the horn. We recommend filtering the final product through a 1 µm filter after the last sonication step to remove it.

On food safety specifically: we hold no ISO certification, cGMP certification, FDA registration or state food permit, and we do not imply one. Material specifications are published above. If you need a specific certification on file, tell us before you order.

Ingredients and Formulation

13. How much NanoOptimizer do I need per kilogram of active?

One kilogram emulsifies approximately 200 g of isolate, distillate or extract. Ratio runs 3:1 to 5:1 by weight. Ratio moves particle size measurably: 5:1 gives roughly 30 nm volume-weighted, 4:1 roughly 40 nm.

Pricing is $795/kg at 1 kg and $700/kg at 10 kg, or $630/kg with code Cannasol10. NanoOptimizer performs optimally with ultrasonic processing, but can be used on other emulsification equipment as well.

14. What is the difference between NanoOptimizer and High-Loader?

What each one was optimized for. NanoOptimizer was optimized for minimum particle size and maximum stability. High-Loader was optimized for higher loading, lower cost and reduced bitterness. Larger particles transmit taste less efficiently, which can be advantageous for bitter actives. Our surfactant systems are tasteless on their own.

Particle sizeNanoOptimizer 20–100 nm · High-Loader 200–250 nm
Practical loading limitNanoOptimizer 75 mg/mL · High-Loader 150 mg/mL
What we recommendNanoOptimizer 50 mg/mL · High-Loader 50–100 mg/mL

We do not recommend acidifying a concentrated High-Loader emulsion much above 100 mg/mL. For powder production, ask for High-Loader P™, made without hygroscopic ingredients. Standard High-Loader can be used, but High-Loader P™ is the one made for it.

15. My product tastes bitter. Will the equipment fix that?

No. Bitterness is a formulation problem. Ultrasonic processing changes droplet size, not flavor chemistry.

We sell 1,3 Propanediol USP/FCC as a bitter blocker, from $70 to $4,369 depending on volume, and an organic bitter blocker powder in 0.25 kg at $695. Both are ordered separately from equipment.

16. Will you make the emulsion for us instead of selling us a machine?

Yes. We produce finished nanoemulsion to specification in our 1,250 sq ft cleanroom and sell it wholesale, business to business.

This suits a brand validating a formulation before committing capital, or one that wants the product without the equipment. Our finished nanoemulsion line is marketed separately at enjoynano.com. We do not sell to consumers.

Buying, Lead Time and Support

17. What is the lead time?

Four to five weeks for a CT-2000, five to six weeks for a turnkey package. Components and ingredients generally ship faster. Custom builds are quoted with their own lead time.

18. Can I just buy this on the website?

You can, but most systems are not ordered that way. Consumables, horns, chambers and accessories go through the cart routinely. A complete system at $20,995 and above is usually a phone call and a purchase order, so the configuration can be confirmed first.

Every standard product carries a published price either way.

19. What does a replacement horn cost, and how long does it take?

$1,295 for the 40 mm flowcell horn. We cut every horn and booster we sell, so replacements ship from stock rather than made to order. A 1.0″ high-gain batch horn, for volumes from 500 mL to 2.0 L, is available on request.

Equipment carries a one-year warranty on non-consumable components. Tubing, gaskets, ultrasonic horns and pump wear components are excluded, because they are consumables.

20. Who provides support after purchase?

Cannasol provides direct technical support after purchase from the same team that handles your equipment or formulation. (216) 921-2240, Monday to Friday, 9:30 AM–5:30 PM Eastern.

Manuals, protocols, SDS documents and ingredient statements are published on the resources page rather than sent on request.

21. Do you ship internationally?

We sell to businesses, not to consumers or hobbyists. Contact us with your location and we will confirm what we can ship.

Question not here?

These questions arrive by phone and email. If yours is missing, call (216) 921-2240; we will answer it and add it here.

Question not answered here?

Call and ask. Most answers take one call.

Cannasol Technologies LLC8101 Uzita Drive
Sarasota, Florida 34240, United States

(216) 921-2240

josh.detzel@cannasolusa.com

Monday–Friday, 9:30 AM–5:30 PM Eastern

Contact Us

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
© Copyright 2026 Cannasol Technologies LLC Privacy policy · (216) 921-2240