How Ultrasonic Emulsification Works

High-frequency vibration at the horn creates cavitation, the rapid formation and collapse of microscopic vapor bubbles. As those bubbles collapse, they generate intense shear forces that reduce particle and droplet size.

The Cannasol 40 mm horn driving cavitation at its output face Side profile of the Cannasol 40 mm Grade 5 titanium horn, V24 rev B: 125.21 mm long, a 39.35 mm driven body, a 45.70 mm nodal flange, a 21.10 mm neck and a 39.00 mm output face. Vibrating 20,000 times per second, the flat output face drives pressure waves down into the liquid, where vapor bubbles form and collapse. Smaller waves leave the upward-facing surfaces of the wide tip. Liquid surface 39 mm output face 20 kHz · 100 micron amplitude Cavitation bubbles form, then collapse Microjets break up particles

The 40 mm horn, V24 rev B. Actual output amplitude is determined by horn geometry, booster gain, and the generator's power setting.

20 kHzOperating frequency
100 micronAmplitude with the included 2:1 booster
2.0–8.0 kWSystems for laboratory and industrial applications
As small as 20–30 nmVolume-weighted average by DLS

Acoustic Cavitation

A titanium horn vibrating at 20 kHz creates alternating pressure cycles in the liquid, forming microscopic vapor cavities that rapidly collapse. This process generates intense localized shear that breaks droplets and particles into smaller, more uniform sizes.

The collapsing cavities generate the shear forces that drive particle and droplet size reduction. Each collapsing bubble generates intense local shear over a short distance. Oil droplets caught in that shear field are torn into smaller droplets. Repeat this several million times per second across the horn face and a coarse emulsion becomes a nanoemulsion.

The life of a cavitation bubble across one pressure cycle A sound wave alternately stretches and compresses the liquid. A vapor bubble nucleates in the stretched half-cycle, grows, then collapses asymmetrically and creates a micro-jet. Pressure at the horn face compression rarefaction Nucleation the liquid tears open Growth vapor fills the cavity Asymmetric collapse one side caves in first Micro-jet and shear breaks up droplets One cycle. This repeats 20,000 times a second, across the whole horn face.
One pressure cycle at the horn face. The bubble nucleates in the stretched half-cycle, grows, then collapses unevenly and creates a micro-jet.
The takeaway Ultrasonic energy is concentrated into a small processing zone around the horn. Horn and flow-cell geometry determine how effectively that energy reaches the liquid.

This is why vessel geometry matters as much as generator rating. Our reactor chamber is CNC-milled from a single block of 316L stainless steel to achieve a geometry that forces the liquid through the cavitation zone, rather than around it. A flow cell with the right internal geometry puts every milliliter through the cavitation field. A bucket with a probe in it does not.

An ultrasonic liquid processor is also called a sonicator, or an ultrasonic homogenizer. All three names describe the same machine: a generator, a converter, a booster and a horn that drives cavitation in the liquid at the horn face. Cannasol machines the horn, the booster and the reactor chamber in-house.

Ultrasonic converter and horn mounted in a stainless reactor chamber with tri-clamp fittings and hose barb connections
Continuous-flow horn and reactor assembly.
Ultrasonic converter and horn on a laboratory stand with the horn tip immersed in a beaker of liquid
Benchtop horn and converter assembly.

Amplitude Matters as Much as Power

Amplitude is the physical distance the horn tip travels each cycle, and it is the variable that decides whether cavitation happens at all. Higher generator wattage does not necessarily mean more cavitation.

A Cannasol system reaches 100 micron amplitude with the included 2:1 half-wave Grade 5 titanium booster. The booster is a mechanical transformer: it trades force for displacement, so the horn tip moves further than the transducer alone would drive it. Change the booster ratio and you change the amplitude, with the same generator behind it.

Below a certain amplitude threshold, sonication does not induce enough cavitation to effectively break up particles. Throughout history it has been challenging to achieve high amplitude with large surface area probes. Cannasol's unique horn designs allow for both high surface area and high amplitude.

How we answer itDelivered power at the probe is 1.2–1.6 kW of actual output for a 2,000W power supply (fluid viscosity dictates precise output). No system runs at 100% of rated power, and we are upfront about true output power of our systems.
The booster trades force for displacement A side elevation of the stack: converter, then a 2 to 1 half-wave booster, then the horn. The horn narrows to a neck and expands again to the output face. The whole stack vibrates along its own axis, so the output face travels left and right, not up and down. A Cannasol system reaches 100 micron amplitude peak to peak. Converter 20 kHz / 20 µm Booster 2:1 half-wave 2:1 Booster 40 mm high-gain horn 100 micron
The booster is a mechanical transformer. It trades force for displacement, so the tip travels further than the transducer alone would drive it.

Two things happen at once, and they fight each other

During high-energy emulsion formation there are two processes occurring simultaneously. Shear forces split larger particles into smaller ones. At the same time, the high-energy environment drives particle collisions that recombine two small particles into one larger one.

The second process is why loading has a ceiling. The lower the dispersed-phase percentage, the smaller and more uniform the emulsion can become, because recombination happens more slowly when the particles are further apart.

What makes a nanoemulsion stable?

Distance. An emulsion destabilizes when particles find each other and combine. The further apart they are, the more temperature and pH abuse the emulsion tolerates.

The simplest way to think about it For an emulsion to break, setting aside Ostwald ripening, the particles have to find each other to agglomerate or combine. The further apart the particles, the more aggressive the conditions an emulsion will survive. That is why the same surfactant holds better at lower loading.

There are two ways to stabilize an emulsion: charge stabilization, which relies on zeta potential (highly pH dependent), and steric stabilization, which relies on bulky surface groups to prevent particles from coming into close proximity. A surfactant system using both is more stable at higher loading than one using either alone.

Charge stabilization and steric stabilization Two ways of keeping oil droplets apart. Charge stabilization relies on zeta potential and is highly pH dependent. Steric stabilization relies on bulky surface groups. Charge stabilization Like charges repel. −−− −−− −−− −−− Highly pH dependent Steric stabilization Bulky surface groups hold droplets apart. Holds at higher loading
Charge stabilization holds droplets apart with like charges and moves with pH. Steric stabilization holds them apart with bulky surface groups.

How is droplet size measured?

Droplet size is measured by dynamic light scattering, and the number is meaningless without knowing which average was reported. DLS instruments can report intensity-weighted, volume-weighted or number-weighted averages from the same sample, and the three can differ substantially.

Our systems produce droplets as small as 20–30 nm, stated as a volume-weighted average by DLS. NanoOptimizer™ yields 20–100 nm depending on usage conditions. Where you land depends on the active, the carrier oil, the surfactant ratio and residence time.

A 5:1 surfactant-to-active ratio gives roughly a 30 nm volume-weighted average. 4:1 gives roughly 40 nm. You will see the difference in clarity, because excellent clarity requires essentially zero particles above 100 nm.

Dynamic light scattering droplet size distribution trace for a Cannasol nanoemulsion, normalized volume against particle size in nanometers, peaking near 20 nm
DLS distribution trace. Volume-weighted average, measured in-house.

Not sure your material will run?

If it pours freely at room temperature, we can process it.

Cannasol Technologies LLC8101 Uzita Drive
Sarasota, Florida 34240, United States

(216) 921-2240

josh.detzel@cannasolusa.com

Monday–Friday, 9:30 AM–5:30 PM Eastern

Contact Us

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
© Copyright 2026 Cannasol Technologies LLC Privacy policy · (216) 921-2240